EKA/EKA NV/EKA NI/EKA NIS

Similar documents
Gateways DALIK v Programming manual

AUTOMATION. Presents DALI

Albeo LED Luminaire. GE Lighting. ABHG Series DATA SHEET. Optics. Product information. Installation. Structures and materials.

SUBMERSIBLE PUMPS & MOTORS

DALI Sensors from OSRAM

DALI USB Interface Device

UNDER-DESK MULTI-OUTLETS

CENTRAL STATION EZ PSC-A64GT

CENTRAL STATION EZ PSC-A64GT

Padlocks manufactured in Sweden since 1930

APRIL 2017 KNX DALI-Gateways DG/S x BU EPBP GPG Building Automation. Thorsten Reibel, Training & Qualification

Carolina Bachenheimer-Schaefer, Thorsten Reibel, Jürgen Schilder & Ilija Zivadinovic Global Application and Solution Team

Chip Inductor (CIL Series)

TECHNICAL CATALOGUE. diaphragm safety relief valves

TECHNICAL CATALOGUE DIAPHRAGM SAFETY RELIEF VALVES

axxys origins Fitting Instructions

Bronkhorst. Bronkhorst High-Tech Frank Doornbos. Bronkhorst Cori-Tech Erwin Eekelder. Expertise in MASS FLOW and PRESSURE meters and controllers

Introduction...2. Solar Radiation...3 Solar Sensor...3. Components...4. System Operation...6

GAS VALVE CROSS REFERENCE

User Manual Revision English

Refrigeration Training System

DALI Expander. Datasheet. Expander with Power Supply. device for simple DALI circuit expansion with integrated Bus power supply

2013 NRC Regular Category BOROBUDUR SHRINE RESTORATION

DALI HELP & TROUBLESHOOTING

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

CENTUM - components list

Ingersoll Rand Manual 600 Compressor READ ONLINE

fitting instructions axxys evolution

Lunatone DALI Light Management Systems DALI BUS SYSTEM CONTROLS & HMIS INTERFACES & TOOLS OPERATING DEVICES & ACTUATORS WIRELESS DALI

DALI power line communication

6. Geberit Floor Drainage Systems

Presenting DALI Control your light easy, versatile and digital:

Refrigerator מקרר DN161220X DN DN162220

Wires, Wire Splicing and Termination

CENTUM - components list

Brian D's Naim Hi-Fi to Ella Mk1 EL34 P-P

E-BOOK # PROFORM 470 HR MANUAL DOCUMENT

New: DALI Gateways Launch Presentation

DTC B1421 SOLAR SENSOR CIRCUIT (PASSENGER SIDE)

M E M O R A N D U M. Technical Committee on Tactical and Technical Operations Protective Clothing and Equipment

Houghton Mifflin MATHEMATICS

PD-C PD-CS. English Printed: Doc-Nr: PUB / / 000 / 00

DEPARTMENT OF BOTANY UNIVERSITY OF LUCKNOW LUCKNOW TENDER NO.: DST-PURSE 01/Bot./LU Dated: March 8 th 2013

Riser-Gard Frequently Asked Questions

Why Is Epistemic Evaluation Prescriptive?

1: adapt. 2: adult. 3: advocate. 4: aid. 5: channel. 6: chemical. 7: classic. Appears in List(s): 7a Level: AWL

Temperature Sensors: Plastic Applications Thermocouples

APAS assistant flexible production assistant

First Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement. Ballot Results 6/17/ :35 AM

This test accounts for 20% of the Final mark

E32-DE-IDM-32. Opto-Isolated I/O Board

MINI CONTINUUM II CONTINUOUS LINES OF LIGHT.

PERU NUEVA PERLITA COMMUNITY. The Filbey Family Windham Presbyterian Church 2016 INVESTMENT

ABB STOTZ-KONTAKT GmbH ABB i-bus KNX DGN/S DALI Gateway for emergency lighting

Ambient Lighting: The New Look of Night-time Driving

Greystone Baptist Church Columbarium Policies and Procedures

Unit 5: Inverse Functions

Digital Logic Lecture 5 Boolean Algebra and Logic Gates Part I

USHER PROCEDURES Berwyn United Methodist Church

Calvary Baptist Church Operations Manual

The load carrier system designed for professionals

USHER PROCEDURES Berwyn United Methodist Church

DEPARTMENT OF ZOOLOGY UNIVERSITY OF LUCKNOW LUCKNOW RE-TENDER. TENDER NO.: PURSE-02/Zool-LU/2015. Dated: May 11, 2015

Module 6: Inverse Functions

Geberit Dual Flush Valve Manual

Year 4 Medium Term Planning

M E M O R A N D U M. NFPA Technical Committee on Gaseous Fire Extinguishing Systems

Roll Call: Betsy Brian, Steve Guitar, Rick Jimenez, Jon Wahrenbrock and Paul Gardner.

Cornerstone EPC Facilities Use Agreement. Revised

Establishment of a Microfilm Section at the King Abdul Aziz University, Jeddah

RIRS V EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. Lüftungsgeräte mit Wärmerückgewinnung

Year 4 Medium Term Planning

FIGURE The SIFRA Compendium. AWRD Tools menu option. Open Introduction of SIFRA. Open SIFRA File for Specific Country

Six Sigma Prof. Dr. T. P. Bagchi Department of Management Indian Institute of Technology, Kharagpur

Skatium Ice Rink Advisory Board Minutes February 20, The next Meeting is scheduled for: March 20, 7:30 p.m. at the Skatium, 2 nd Floor

Ushers & Greeters Guide to Everything. About Everything. June 9

TITLE PAGE. An Expert System for measuring shear-wave splitting. above small earthquakes

Farm Series Extension Tier

Introduction to the NATO Codification System

Decision-Making and the Will of God Part 1

Rental Information. Welcome. Church Facilities and Parking. Bookings

Industrial Embedded Systems - Design for Harsh Environment -

EE-100 Engineering Laboratory Module1: PCB

MOVED by Bud Gibbons, SECONDED by Anne Miller that the agenda be approved. CARRIED

Episode 4 ADAM AND EVE. PROOF TEXT Genesis 2, 3

Inside This Issue...

c l o s e t s o l u t i o n s

Features ADDICT - V3. DALI AC mains immunity with warning, higher DALI line ~20VDC, more efficient with longer battery life, a

PZ is a student I worked with during my special education practicum this past

Software Modelling For Real World Faults On AC Transmission Protective Systems Analysis And Effects

Gaskets. Flat Gaskets made of Aramide, EPDM, FKM, NBR, PTFE and Graphite. Reichelt Chemietechnik 14

Opening Reflection Fr. Shaun Eaton. Shaun spoke about some of the principles of an effective team, and led us in prayer.

St Mary s Church Hall

Members present: John Antona (Chair), Tim Newton (Vice Chair), Tim Mowrey, Charles Waters, Jerry Wooldridge

Safety in Shanghai. Donard de Cogan

- M : Musso, I : M100, K : Korando, C : Chairman, R : Rexton - A : Mandatory Basic, B : Extended Mandatory Basic, C : Commercially Available

Islamic architecture: between moulding and flexibility

Descartes Method of Doubt

Module - 02 Lecturer - 09 Inferential Statistics - Motivation

Rüegg Surprise. And the cold leaves you cold!

Transcription:

Electric duct heater Elektrinis kanalinis šildytuvas Elektryczna nagrzewnica kana wa Electric heaters are designed to heat clean air in ventilation systems. Casing is made from aluzinc coated steel which is high temperature proof. Heating elements tube is made from stainless steel AISI 304. In heaters are installed 2 protection thermostats, screw terminals for easy connection. Casing is with rubber seals for duct connection. Heaters can be installed vertically or horizontally. Maximum output air temperature 50 C. Elektriniai kanaliniai šldytuvai skirti švaraus oro pašildymui ventiliacijos sistemose. Korpusai pagaminti iš skardos, padengtos alucinku gimo gnybtai. Korpusas yra su sandarinimo gumomis, pajungimui nia czystego powietrza w systemach wentylacyjnych. Obudowa wy- - - bezpieczenia termiczne. - - temperatury na obudowie. lator pomieszczeniowy TR5K) - - - - - - Accessories Controller for electrical heater Controller for electrical heater Duct sensor EKR 6.1 p. 170 EKR 15.1 p. 168 TJK 10K p. 173 156

All dimensions in mm * Dimensions of 12 kw heaters Technical data Type Diameter [mm] [m 3 /h] Power [kw] Nominal current, I n [A] 100 40 1~ 230 0,3/0,6/0,9/1,2 1,4/2,8/4,1/5,5 125 70 1~ 230 0,3/0,6/0,9/1,2/1,5/1,8 1,4/2,8/4,1/5,5/6,8/8,2 160 110 200 170 250 270 315 415 400 690 500 1060 3~ 400 6,0 8,7 3~ 400 6,0 8,7 3~ 400 6,0/9,0 8,7/13,0 3~400 6,0/9,0/12,0 8,7/13,0/17,3 3~ 400 6,0/9,0/12,0 8,7/13,0/17,3 3~ 400 6,0/9,0/12,0/15,0 8,7/13,0/17,3/21,6 Electrical heaters conforms to requirements of standards IEC 60335-2-30 : 1996, LST EN 600335-2-30 : 1999, LST EN 61010-1+A2 : 2000, LST EN 50081-2 : 1995, LST EN 55011 : 1999+A1 : 2001and carries CE mark. Type Accessories EKR 6.1 (1,2 - phase) EKR 15.1 (3 - phase) TJK 10K 100 + - + 125 + - + 160 + + + 200 + + + 250 + + + 315 + + + 400 + + + 500 + + + 157

EKA/EKA NV/ EKA NI/EKA NIS 100-1,2 EKA/EKA NV/ EKA NI/EKA NIS 100-0,9 EKA/EKA NV/ EKA NI/EKA NIS 100-0,6 EKA/EKA NV/ EKA NI/EKA NIS 100-0,3 EKA/EKA NV/ EKA NI/EKA NIS 125-2,4 EKA/EKA NV/ EKA NI/EKA NIS 125-1,8 EKA/EKA NV/ EKA NI/EKA NIS 125-1,5 EKA/EKA NV/ EKA NI/EKA NIS 125-1,2 EKA/EKA NV/ EKA NI/EKA NIS 125-0,9 EKA/EKA NV/ EKA NI/EKA NIS 125-0,6 EKA/EKA NV/ EKA NI/EKA NIS 125-0,3 EKA/EKA NV/ EKA NI/EKA NIS 160-6,0 EKA/EKA NV/ EKA NI/EKA NIS 160-5,0 EKA/EKA NV/ EKA NI/EKA NIS 160-3,0 EKA/EKA NV/ EKA NI/EKA NIS 160-2,4 EKA/EKA NV/ EKA NI/EKA NIS 160-2,0 EKA/EKA NV/ EKA NI/EKA NIS 160-1,2 158

EKA/EKA NV/ EKA NI/EKA NIS 200-6,0 EKA/EKA NV/ EKA NI/EKA NIS 200-5,0 EKA/EKA NV/ EKA NI/EKA NIS 200-3,0 EKA/EKA NV/ EKA NI/EKA NIS 200-2,4 EKA/EKA NV/ EKA NI/EKA NIS 200-2,0 EKA/EKA NV/ EKA NI/EKA NIS 200-1,2 EKA/EKA NV/ EKA NI/EKA NIS 250-9,0 EKA/EKA NV/ EKA NI/EKA NIS 250-6,0 EKA/EKA NV/ EKA NI/EKA NIS 250-5,0 EKA/EKA NV/ EKA NI/EKA NIS 250-3,0 EKA/EKA NV/ EKA NI/EKA NIS 250-2,4 EKA/EKA NV/ EKA NI/EKA NIS 250-2,0 EKA/EKA NV/ EKA NI/EKA NIS 250-1,2 EKA/EKA NV/ EKA NI/EKA NIS 315-12,0 EKA/EKA NV/ EKA NI/EKA NIS 315-9,0 EKA/EKA NV/ EKA NI/EKA NIS 315-6,0 EKA/EKA NV/ EKA NI/EKA NIS 315-3,0 EKA/EKA NV/ EKA NI/EKA NIS 315-2,0 159

EKA/EKA NV/ EKA NI/EKA NIS 400-12,0 EKA/EKA NV/ EKA NI/EKA NIS 400-9,0 EKA/EKA NV/ EKA NI/EKA NIS 400-6,0 EKA/EKA NV/ EKA NI/EKA NIS 400-5,0 EKA/EKA NV/ EKA NI/EKA NIS 400-3,0 30 25 20 15 EKA/EKA NV/ EKA NI/EKA NIS 500-6,0 10 5 160

Overheat protection stage switches on when the temperature reaches 50 C (resets automatically), the second stage switches on when the temperature reaches 100 C (is reset manually with pushbutton on the casing). EKA has no internal temperature controller. External heating controllers EKR are used in this case. Heaters with internal temperature EKA...NV Heaters with integrated temperature controller, temperature setpoint internal temperature regulator which works by algorithm impulse/pause, triacs without moving parts, which causes no-noise commutation. Potentiometer is used to set temperature. Manual termocontact restoration button and temperature setpoint are located on the case of a heater. The duct temperature sensor is needed. EKA...NI Heaters with integrated temperature controller, temperature setpoint external Heaters EKA...NI with integrated temperature control, contains temperature regulator which works by algorithm impulse/pause, that without moving parts, which causes no-noise commutation. External temperature setpoint must be connected separately. The button of manual restoration located on the case of a heater. The duct temperature sensor and potentiometer is needed. EKA...NIS Heaters with integrated temperature controller, external control signal Heaters EKA...NIS with integrated temperature control, contains temperature regulator which works by algorithm impulse/pause, triacs without moving parts, which causes no-noise commutation. The button of manual restoration located on the case of a heater. On-time and Off-time is varied 0-100% to suit the prevailing heat demand. Temperature regulator EKR-K... Ambient temperature: 0-40 C Humidity: max 80% Adjustment range of temperature: 0-30 C. Temperature is adjusted by: internal or external potentiometer. Input signal for temperature control: The PCB is equipped with internal fuses F1 and F2 on 50 ma. Their applicability, to protect PCB from the increased current. 161

EKA NV connection diagram EKA NI connection diagram EKA NIS connection diagram 162